Description
S1600 ICU Ventilator
_x000D_
Friendly Powerful Reliable_x000D_
Applications
_x000D_
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Intra-operation, post-operation respiratory support, other respiratory treatment._x000D_
Trust Points
_x000D_
_x000D_
- Simplicity: easy to use, easy to move with 4 wheels.
_x000D_
- Choice: adapt the equipment to your patients and procedures freely
_x000D_
- Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 5 modes: IPPV; A/C; SIMV; SPONT/CPAP; MANU.
_x000D_
- Designed and manufactured by Superstar Medical with over 23 years experience in this area.
_x000D_
- Flexible configurations to suit your needs.
_x000D_
- International standard and advanced technology suitable for wide range use.
_x000D_
- Compact interface and big screen give you better operating experience.
_x000D_
- Over 2,000 units installed in the world.
_x000D_
_x000D_
Features
_x000D_
_x000D_
- 10.4 inch TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.
_x000D_
- Recycle breathing pipe, ensure easy operating and keep tidy.
_x000D_
- Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
_x000D_
- Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
_x000D_
- Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;
_x000D_
- Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.
_x000D_
- Venturi effect technology ensure the machine working without air gas source.
_x000D_
- Safety
_x000D_
- Three level alarming system, visual and sound alarm information.
_x000D_
- With lots of alarming, reminding and protection functions.
_x000D_
- Advanced power management control technology.
_x000D_
- With built-in backup power source, when outside power source goes off, back-up power source starts to work.
_x000D_
- Self-check before running, eliminate system mistake.
_x000D_
- Separate design of electric and gas, keep safety running of ventilator.
_x000D_
_x000D_
Specifications
_x000D_
_x000D_
_x000D_
_x000D_
| Ventilation modes: |
_x000D_
IPPV; A/C; SIMV; SPONT/CPAP; MANU |
_x000D_
_x000D_
_x000D_
| Ventilator parameter ranges |
_x000D_
|
_x000D_
_x000D_
_x000D_
| Tidal volume(Vt) |
_x000D_
0, 20 mL ~ 1500 mL |
_x000D_
_x000D_
_x000D_
| Frequence(Freq) |
_x000D_
1bpm ~ 100 bpm |
_x000D_
_x000D_
_x000D_
| I/E |
_x000D_
4:1~1:8 |
_x000D_
_x000D_
_x000D_
| PEEP |
_x000D_
0cmH2O ~ 20 cmH2O |
_x000D_
_x000D_
_x000D_
| Pressure triggering sensitivity(PTr) |
_x000D_
ï¼20 cmH2O ~ 0 cmH2O(Based on PEEP) |
_x000D_
_x000D_
_x000D_
| SIGH |
_x000D_
0(off) 1/100 ~ 5/100 |
_x000D_
_x000D_
_x000D_
| Apnea Ventilation |
_x000D_
OFF,5 s ~ 60 s |
_x000D_
_x000D_
_x000D_
| Monitored Parameters |
_x000D_
|
_x000D_
_x000D_
_x000D_
| Frequence(Freq) |
_x000D_
0 /min ~ 100 /min |
_x000D_
_x000D_
_x000D_
| Tidal volume(Vt) |
_x000D_
0 mL ~ 2000 mL |
_x000D_
_x000D_
_x000D_
MV_x000D_
_x000D_
Airway pressure |
_x000D_
0 L/min ~ 99 L/min_x000D_
_x000D_
0cmH2O ~ 100cmH2O |
_x000D_
_x000D_
_x000D_
| Oxygen concentration |
_x000D_
15 % ~ 100 % |
_x000D_
_x000D_
_x000D_
| Graphical display: |
_x000D_
|
_x000D_
_x000D_
_x000D_
| P-T(pressure – time) |
_x000D_
|
_x000D_
_x000D_
_x000D_
| F-T(flow – time) |
_x000D_
|
_x000D_
_x000D_
_x000D_
Size_x000D_
_x000D_
1.Wooden case packing size(main engine):L 560*W 560*H 615mm , GW:35KG ; NW:17KG_x000D_
_x000D_
2.Wooden case packing size(trolley):L650*W690*H 520 mm , GW:38KG NW:18G_x000D_
_x000D_
Alarm and protection |
_x000D_
_x000D_
_x000D_
| The AC power failure alarm |
_x000D_
Power failure or no connection |
_x000D_
_x000D_
_x000D_
| Internal battery backup low voltage alarm |
_x000D_
<11.3±0.3V |
_x000D_
_x000D_
_x000D_
| No tidal volume |
_x000D_
No tidal volume within 6s |
_x000D_
_x000D_
_x000D_
High oxygen concentration alarm_x000D_
_x000D_
Low oxygen concentration alarm |
_x000D_
19%-100%_x000D_
_x000D_
18%-99% |
_x000D_
_x000D_
_x000D_
High Airway pressure alarm_x000D_
_x000D_
Low Airway pressure alarm_x000D_
_x000D_
High Minute Volume alarm_x000D_
_x000D_
Low Minute Volume alarm_x000D_
_x000D_
Continuous Pressure alarm |
_x000D_
20cmH2O-100cmH2O_x000D_
_x000D_
0cmH2O-20cmH2O_x000D_
_x000D_
1L/min-99L/min_x000D_
_x000D_
0-20L/min_x000D_
_x000D_
(PEEP+1.5kPa) over 16s |
_x000D_
_x000D_
_x000D_
| Suffocation warning |
_x000D_
5s-60s no spontaneous ventilation |
_x000D_
_x000D_
_x000D_
| Working conditions |
_x000D_
|
_x000D_
_x000D_
_x000D_
| Gas source |
_x000D_
O2, |
_x000D_
_x000D_
_x000D_
| Pressure |
_x000D_
280kPa-600kPa |
_x000D_
_x000D_
_x000D_
| Voltage |
_x000D_
-220V±22V |
_x000D_
_x000D_
_x000D_
| Power frequency |
_x000D_
50Hz±1Hz |
_x000D_
_x000D_
_x000D_
| Input power |
_x000D_
40VA |
_x000D_
_x000D_
_x000D_
_x000D_
Reviews